Установите Flash player для полного просмотра сайта!
Research-and-production association «NATEK»
|
About
Production
Heat-exchange equipment
Heat-exchange devices
INT and IKT vaporizers
IKh vaporizers
KVNG and KVKG vaporizers
IU vaporizers
TPG and TU devices
Delivery water heaters
Hot water converters
Sectional heaters
PN-100 … PN-850 low-pressure heaters
Drainage coolers
Subsidiary water-to-water heat exchangers
Oil coolers
Fuel oil heaters
Storage equipment
Storage devices
Mixer devices
Air collectors
GS1 and GS2 gas separator
NGS1 and NGS2 oil separators
Open-type deaerators
Reservoirs
Dust collecting devices and their blocks
Methanol storage containers
FIPa1 filters
Graphite chemical devices
Graphite block-housing heat exchangers
Graphite tube-housing heat exchangers
Tower graphite devices
Graphite tube-housing absorbers
Tower equipment
Tower equipment
Reactor equipment
Reactor equipment
Isoprene synthesis reactor
Irregular equipment
101SA/SV waste-heat boiler tube pack
RG 420 S boiler water pre-heater
KN-80/40 economizer tube block
Waste-heat boiler, pos. 102-S
Waste-heat boiler, pos. 103-S
Steam-jet injector
Spreading unit
Flares
Компенсаторы сильфонные
Metallurgic equipment
Ladles
Partner
Order
Contacts
Order
Expanded order form for heat exchange devices
Новости
12.02.2008
5-7.02, Volgograd, Exhibition "Equipment-Oil.Gas.Chemistry" ...
In detail>>
All news >>
Expanded order form for heat exchange devices
Device parameters
1
Device symbolic notation
2
Design and operation conditions. Substance parameters
In tubes
In housing
2.1
Pressure MPa
Oper.m
Design
2.2
Operating temperature
Outlet
Input
2.3
Minimum (pressurized device wall negative temperature)
2.4
Coldest 5-day working week mean temperature of the area
In tubes
In housing
2.5
Substance description and composition by percentage (% mass)
2.6
Substance physical state (gas, steam, liquid)
2.7.а
Substance feature: hazard, GOST 12.1.007 (danger class mention)
2.7.б
Flammability, GOST 12.1.011 «yes» «no»
2.7.в
Explosion hazard, GOST 12.1.011 (category and mixture group mention)
3
Need to attach heat-insulation fixing details «yes» «no»
4
Need to test joint welds for grain-boundary corrosion yes no, if yes, mention the method, GOST 6032 Filled for the devices with grades of steel
5
Mention: links «left», «right», «не требуются»
not applicable (filled only for 600-1,200 mm distribution chamber devices)
6
Heat exchanging devices mounted at: «concrete foundation» «metalware»
7
Mention the tubes fastening type within tube grids: «flaring» «welding & flaring»
8
Distinctions against the prototype
9
Distinctions substantiating
10
Device material
11
Device total mass, kg
Asterisked items
(*)
should be filled
Your address
12.1*
Name of the Customer's organization*
*
12.2*
Contact person *
*
12.3*
Phone number
*
12.4*
E-mail
*
13
Comments